DATE ELECTRICE GENERALE
|
Putere standby (ESP = Emergency standby power) |
kVA |
1500 |
|
|
kW |
1200 |
|
Putere prime (PRP = Prime Power) |
kVA |
1375 |
|
|
kW |
1100 |
|
Factor de putere |
cos ɸ |
0,8 |
|
Tensiune |
V |
230 / 400 |
|
Frecventa |
Hz |
50 |
DATE CONSTRUCTIVE
|
Structura |
- |
carcasa insonorizata |
|
|
Nivel de zgomot ( la 7 m distanta) |
dB |
70 |
|
|
Gabarit |
Lungime ( L ) |
mm |
8600 |
|
|
Latime ( l ) |
mm |
2280 |
|
|
Inaltime ( h ) |
mm |
2750 |
|
Greutate |
kg |
13570 |
|
|
Material sasiu |
- |
otel |
|
|
Material carcasa ( tabla ) |
- |
otel |
|
|
Acoperire |
- |
vopsea |
|
|
Rezervor integrat de combustibil |
- |
da |
|
|
Capacitate rezervor integrat in sasiu |
litri |
2500 |
|
|
Usi laterale (pentru acces interior usor) |
- |
da |
|
|
Balamale din otel inox |
- |
da |
|
MOTOR
|
Producator |
- |
YUCHAI |
|
Model |
- |
YC12VTD1830-D30 |
|
Putere mecanica |
kWm |
1342 |
|
Tip motor |
- |
Diesel |
|
Ciclu de functionare |
- |
4 timpi |
|
Aspiratie |
- |
turbo intercooler |
|
Combustibil |
- |
motorina |
|
Nr. cilindri |
- |
V12 |
|
Cilindree |
litri |
39,2 |
|
Alezaj |
mm |
152 |
|
Cursa |
mm |
180 |
|
Rata de compresie |
- |
14:1 |
|
Racire |
- |
cu apa |
|
Regulator de turatie |
- |
ECU-COMMON RAIL |
|
Viteza de rotatie |
rpm |
1500 |
|
Capacitate baie ulei (max.) |
litri |
210 |
|
Redresor de baterii |
- |
Da |
|
Numar de baterii |
- |
2 |
|
Tensiune baterie |
V |
24 (2 x 12 V) |
|
Rezistenta preincalzire antigel (preheater) |
- |
Da |
ALTERNATOR
| Producator | - | WEG/WATTEK | ||
| Model | - | 355MI90AI | ||
| Putere (standby) | kVA | 1650/1500 | ||
| Factor de putere | - | 0.8 | ||
| Frecventa | Hz | 50 | ||
| Fara perii | - | Da | ||
| Plaja de reglare a tensiunii | % | ±1 | ||
| Izolatie | - | Clasa H | ||
| Protectie | - | IP 23 | ||
| Numar de rulmenti | - | 1 | ||
| Grup electrogen MARRO MYH 1500 I Panoul de control |
PANOUL DE CONTROL
| Producator | - | DEEP SEA | |||
| Model | - | 7320/7420 | |||
| Afisaj | - | LCD | |||
| DATE GENERALE • Masuratori reale ale parametrilor • Display synchroscop • Baterie pentru ceasul intern • Posibilitate de a simula (pentru a invata) pornirile • Programare saptamanala pentru operare • Suport in mai multe limbi • Jurnal cu 400 evenimente (inclusiv timp si parametri) • Free PC software (USB-Modbus-IP Connected) • Central monitoring software FUNCTII • Unitate AMF cu transfer neintrerupt de sarcina • Unitate AAR cu transfer neintrerupt de sarcina • Controller pornire automata • Controller pornire manuala • Controller motor • Unitate de comanada diplay & unitate de control COMMUNICATII • Ethernet • GSM-GPRS(optional) • Intern: modem GPRS (optional) • Monitorizare web • Web programming • GSM-SMS • e -mail • Software de conectare la calculator (gratuit) • Modbus RS-485 • Modbus over IP • SNMP • USB Host(optional) • USB Device • RS-485 • RS-232 (optional) • Micro SD card slot (optional) | |||||
| • J1939-CANBUS |
CONSUM
| 100 % sarcina . | litri / ora | 305.7 | |||
| 75 % sarcina | litri/ ora | 228.3 | |||
| 50 % sarcina | litri/ ora | 158.5 |
CERTIFICARI
| Echipamentul este produs in sistem certificat ISO 9001, ISO 14001 si CE. | |||||
| NOTA: Informatiile si imaginile prezentate in acest document sunt cu titlu informativ si pot suferi modificari fara notificari prealabile | |||||
| Conditiile ambientale de functionare de referinta sunt cele mentionate in normativul ISO 8528-1:2018: 1000 mbar, 25 ºC, umiditate relativa 30%. Prime Power (PRP) - In conformitate cu ISO 8528-1:2018, Prime power (sau puterea continua/de productie) este puterea maxima pe care un generator electric este capabil sa o produca in timp ce furnizeaza o sarcina electrica variabila. Generatorul electric este functional un numar nelimitat de ore / an in conditii cunoascute, cu conditia ca intervalele si procedurile de mentenanta prescrise de producator sa fie respectate. Emergency Standby Power (ESP) - In conformitate cu ISO 8528-1:2018, Emergency standby power (sau puterea in regim de avarie/urgenta, standby) este puterea maxima disponibila furnizata de un generator electric in timpul unei perioade cu variatii de putere electrica, putere pe care generatorul electric este capabil sa o furnizeze in eventualitatea unei caderi a retelei sau in conditii de test, pentru cel mult 500 ore / an. Este obligatorie respectarea intervalelor si procedurilor de mentenanta prescrise de producator |